TensCare Perfect MamaTens Replacement Electrode Pads 4 pads/pk
$27.99
Reusable, self-adhesive replacement electrode pads for use with the Perfect MamaTens maternity TENS unit ONLY.
$27.99
Reusable, self-adhesive replacement electrode pads for use with the Perfect MamaTens maternity TENS unit ONLY.
These 50 x 100mm rectangular maternity electrodes with integrated leads for are use with TensCare Perfect mamaTENS Â only.
To replace electrodes for further use after labour for pain relief, please purchase L-CPT leads and 50 x 100mm electrodes.
Electrode Care Guide
Pre Application
Before applying electrode pads, be sure to wash the skin with warm soapy water to remove any dirt, oil or creams that may be present on the skin. The presence of oils and debris can degrade electrode pads and cause problems with adhesion. Even a quick wipe with an alcohol based skin wipe is great before application.
Application and Removal
Turn off the TENS unit before applying and removing the electrodes. Peel electrodes gently from the corner, do not pull on the wire. Then place on the skin where you are targeting your treatment.
Storage
Electrodes are water-based and may dry out. Between uses they should be stored on the plastic shield in their re-sealable bag and kept in a cool place out of direct sunlight.
Dried-out electrodes
If the electrode gel becomes dry, either spray the gel side with a fine mist of water, or apply a drop of water to the gel side and spread around with fingertip. Leave the electrode for about 10 minutes until it recovers its tackiness.
Over-wet or sticky electrodes
If the electrode gel becomes too soft and sticky, place the electrode in a refrigerator for a few hours, sticky side up.
Electrode life
The life of an electrode varies depending on skin conditions and skin preparation. Electrodes should last about 20-30 applications. Once tackiness is lost and no longer recoverable you should replace the electrodes.
Description
These 50 x 100mm rectangular maternity electrodes with integrated leads for are use with TensCare Perfect mamaTENS Â only.
To replace electrodes for further use after labour for pain relief, please purchase L-CPT leads and 50 x 100mm electrodes.
Electrode Care Guide
Pre Application
Before applying electrode pads, be sure to wash the skin with warm soapy water to remove any dirt, oil or creams that may be present on the skin. The presence of oils and debris can degrade electrode pads and cause problems with adhesion. Even a quick wipe with an alcohol based skin wipe is great before application.
Application and Removal
Turn off the TENS unit before applying and removing the electrodes. Peel electrodes gently from the corner, do not pull on the wire. Then place on the skin where you are targeting your treatment.
Storage
Electrodes are water-based and may dry out. Between uses they should be stored on the plastic shield in their re-sealable bag and kept in a cool place out of direct sunlight.
Dried-out electrodes
If the electrode gel becomes dry, either spray the gel side with a fine mist of water, or apply a drop of water to the gel side and spread around with fingertip. Leave the electrode for about 10 minutes until it recovers its tackiness.
Over-wet or sticky electrodes
If the electrode gel becomes too soft and sticky, place the electrode in a refrigerator for a few hours, sticky side up.
Electrode life
The life of an electrode varies depending on skin conditions and skin preparation. Electrodes should last about 20-30 applications. Once tackiness is lost and no longer recoverable you should replace the electrodes.
TensCare
For nearly 30 years TensCare has been on the cutting edge for pain management and incontinence therapy. Tens (transcutaneous electrical nerve stimulation) and EMS (electrical muscle stimulation) devices are ultra-safe and cover a wide range of pain management and medical therapy. TensCare knows the difference the products make to the quality of life to hundreds of thousands of users. These products improve the quality of life by helping people feel better naturally. They believe that the well-being of one individual can affect the health and the well-being of the people in that individual’s family and community.
ABOUT TENSCARE
For nearly 30 years TensCare has been on the cutting edge for pain management and incontinence therapy. Tens (transcutaneous electrical nerve stimulation) and EMS (electrical muscle stimulation) devices are ultra-safe and cover a wide range of pain management and medical therapy. TensCare knows the difference the products make to the quality of life to hundreds of thousands of users. These products improve the quality of life by helping people feel better naturally. They believe that the well-being of one individual can affect the health and the well-being of the people in that individual’s family and community.
You may also like
-

TensCare Ailment-Specific TENS & EMS Electrodes for Knee Pain Relief
$22.99 Add to cart -

TensCare Ailment-Specific TENS & EMS Electrodes for Back Pain Relief
$23.99 Add to cart -

TensCare Ailment-Specific TENS & EMS Electrodes for Neck Pain Relief
$23.99 Add to cart -

TensCare Replacement li-on battery for Elise Pelvic Floor Exerciser.
$18.99 Add to cart
Description
These 50 x 100mm rectangular maternity electrodes with integrated leads for are use with TensCare Perfect mamaTENS Â only.
To replace electrodes for further use after labour for pain relief, please purchase L-CPT leads and 50 x 100mm electrodes.
Electrode Care Guide
Pre Application
Before applying electrode pads, be sure to wash the skin with warm soapy water to remove any dirt, oil or creams that may be present on the skin. The presence of oils and debris can degrade electrode pads and cause problems with adhesion. Even a quick wipe with an alcohol based skin wipe is great before application.
Application and Removal
Turn off the TENS unit before applying and removing the electrodes. Peel electrodes gently from the corner, do not pull on the wire. Then place on the skin where you are targeting your treatment.
Storage
Electrodes are water-based and may dry out. Between uses they should be stored on the plastic shield in their re-sealable bag and kept in a cool place out of direct sunlight.
Dried-out electrodes
If the electrode gel becomes dry, either spray the gel side with a fine mist of water, or apply a drop of water to the gel side and spread around with fingertip. Leave the electrode for about 10 minutes until it recovers its tackiness.
Over-wet or sticky electrodes
If the electrode gel becomes too soft and sticky, place the electrode in a refrigerator for a few hours, sticky side up.
Electrode life
The life of an electrode varies depending on skin conditions and skin preparation. Electrodes should last about 20-30 applications. Once tackiness is lost and no longer recoverable you should replace the electrodes.
TensCare
For nearly 30 years TensCare has been on the cutting edge for pain management and incontinence therapy. Tens (transcutaneous electrical nerve stimulation) and EMS (electrical muscle stimulation) devices are ultra-safe and cover a wide range of pain management and medical therapy. TensCare knows the difference the products make to the quality of life to hundreds of thousands of users. These products improve the quality of life by helping people feel better naturally. They believe that the well-being of one individual can affect the health and the well-being of the people in that individual’s family and community.
You may also like
-

TensCare Ailment-Specific TENS & EMS Electrodes for Knee Pain Relief
$22.99 Add to cart -

TensCare Ailment-Specific TENS & EMS Electrodes for Back Pain Relief
$23.99 Add to cart -

TensCare Ailment-Specific TENS & EMS Electrodes for Neck Pain Relief
$23.99 Add to cart -

TensCare Replacement li-on battery for Elise Pelvic Floor Exerciser.
$18.99 Add to cart
![[:en]perfect mamatens pads web[:]](https://www.motherschoiceproducts.com/wp-content/uploads/2021/10/perfect-mamatens-pads-web.jpeg)






![[:en]perfect mamatens pads web[:]](https://www.motherschoiceproducts.com/wp-content/uploads/2021/10/perfect-mamatens-pads-web-100x100.jpeg)










